Source content
FAA Guide for Aviation Medical Examiners · Version 10/28/2026 · page 685
AASI for Cardiac - Single Valve Replacement or Repair
All Classes
(Updated 01/27/2021)
AME Assisted Special Issuance (AASI) is a process that provides AMEs the ability to re-issue an airman medical
certificate under the provisions of an Authorization for Special Issuance of a Medical Certificate (Authorization) to an
applicant who has a medical condition that is disqualifying under Title 14 of the Code of Federal Regulations (14
CFR) part 67.
An FAA physician provides the initial certification decision and grants the Authorization in accordance with 14 CFR §
67.401. The Authorization letter is accompanied by attachments that specify the information that treating physician(s)
must provide for the re-issuance determination. If this is a first-time application for an AASI for the above
disease/condition, and the applicant has all the requisite medical information necessary for a determination, the AME
must defer and submit all of the documentation to the AMCD or RFS for the initial determination.
AMEs may re-issue an airman medical certificate under the provisions of an Authorization, if the
applicant provides the following:
Authorization granted by the FAA
ECG - Required annually.
Echo - Current 2D echocardiogram performed within 90 days
INRs for Mechanical Heart Values - A minimum of monthly International
Normalized Ratio (INR) results for the immediate prior six months
Status report - performed within the past 90 days in accordance with the appropriate
st nd rd
CHD Protocol (1 or 2 Class; 3 Class)
The AME must defer medical certification if the applicant has:
• Additional valve procedure performed;
• Any other disqualifying medical conditions or therapy not previously reported;
• Any other reason for not renewing an AASI;
• Arrhythmia, new onset, such as of atrial fibrillation/flutter, ventricular bigeminy,
ventricular tachycardia, Mobitz Type II or greater AV block, complete heart block, RBBB,
LBBB, or LVH
• Bleeding that required medical intervention or other;
• Echo reveals:
IF ANY OF THE FOLLOWING ARE NOTED ON ECHO, THE AME MAY NOT ISSUE.
Any valve Perivalvular leaking
Aortic Valve Area post procedure is less than 1.0 cm2
Aortic Valve Peak gradient level is 60 mmHg or more
Aortic Valve Mean gradient is 40 mmHg or more
Mitral Valve Any evidence of worsening of mitral valve regurgitation or stenosis in narrative
• Emboli or thrombosis develop
• INR - More than 20% of INR values are less than 2.5 or greater than 3.5.
o In select cases of a Bileaflet (St. Jude) valve in the aortic position, INR values
between 2.0 and 3.0 may be accepted (check with FAA)
• New Event - Has another event, develops a new condition or identification of an
additional cardiac condition not previously reported.
Shown as extracted from the FAA PDF, without paraphrasing. Tables and forms may lose their layout. Underlined references open the Guide location they name.
FAA Guide for Aviation Medical Examiners, Version 10/28/2026, page 685. AME Copilot is an independent reference tool, not affiliated with or endorsed by the FAA. The FAA AME Guide is the authoritative source.