FAA Guide for Aviation Medical Examiners · Version 10/28/2026 · page 525 · page 1 of 4 of this heading
Protocol for Cardiac Valve Replacement
(Updated 05/29/2024)
For applicants with tissue or mechanical valve replacement(s):
INITIAL CONSIDERATION:
• First- or Second-Class Applicants: Applicants may be reviewed by the Federal Air
Surgeon's (FAS) Cardiology Panel or FAS Cardiology Consultant and must have a 6-
month recovery period after procedure to ensure stabilization.
• Multiple heart valve replacement(s): Applicants who have received multiple heart valve
replacements may be considered.
• Ross Procedure: The FAA may consider certification of all classes of applicants who
have undergone a Ross Procedure (pulmonic valve transplanted to the aortic position
and pulmonic valve replaced by a bioprosthesis).
• Transcatheter Aortic Valve Replacement (TAVR) Procedure: TAVR may also be
considered for any class.
• The following information must be submitted for all classes:
1. Copies of all hospital/medical records pertaining to the valve replacement:
• Admission History & Physical (H&P);
• Discharge summary;
• Operative report with valve information (make, model, serial number and size);
and
• Pathology report
2. A current report from the treating cardiologist regarding the status of the
cardiac valve replacement. It should address your general cardiovascular
condition, any symptoms of valve or heart failure, any related abnormal physical
findings, and must substantiate satisfactory recovery and cardiac function without
evidence of embolic phenomena, significant arrhythmia, structural abnormality, or
ischemic disease.
3. If on warfarin (Jantoven), the attending physician must confirm stability without
complications. Report must include warfarin (Jantoven) dose history, schedule,
and International Normalized Ratio (INR) values (monthly for the past 6-month
period of observation; must be within acceptable range).
4. Current 24-hour Holter monitor evaluation to include select representative
tracings.
5. Current M-mode, 2-dimensional, and M-Mode Doppler echocardiogram,
specifically including chamber dimensions and valvular gradients. Submit the
video resulting from this study on CD-ROM in DICOM compatible format.
6. If cardiac catheterization and coronary angiography have been performed, all
reports AND films must be submitted, including a copy of the cineangiogram on
CD-ROM in DICOM compatible format.
Shown as extracted from the FAA PDF, without paraphrasing. Tables and forms may lose their layout. Underlined references open the Guide location they name.
What else should I look at?
Navigation aids drawn from the Guide's own structure and explicit cross-references. They are not medical or certification decisions.
FAA Guide for Aviation Medical Examiners, Version 10/28/2026. AME Copilot is an independent reference tool, not affiliated with or endorsed by the FAA. The FAA AME Guide is the authoritative source. Types such as “Protocol” are reading aids; AME Copilot does not make certification decisions.
Section in the same chapter: DISEASE PROTOCOLS · page 521